SS 304 / 304L Pipe Fittings Supplier in Mumbai, India

STAINLESS STEEL PIPE FITTINGS
Metals Fabrica supplies ASTM A403 / ASME SA403 WP304 and WP304L butt-weld fittings and ASTM A182 F304 / F304L forged fittings, including dual-certified 304/304L, to ASME B16.9 and B16.11.
Pipe fittings
OVERVIEW

SS 304 / 304L Pipe Fittings Overview

SS 304 pipe fittings are made from 18% chromium, 8% nickel austenitic stainless steel, the general-purpose grade of the 300 series. Under ASTM A403 the butt-weld grades are WP304 (UNS S30400) and WP304L (UNS S30403); the forged equivalents under ASTM A182 are F304 and F304L. They suit fresh water, food products, nitric acid and most atmospheric and mildly corrosive service, and remain tough at cryogenic temperatures.

The difference between the two is carbon. WP304 allows up to 0.08%, while WP304L is limited to 0.030%. A fitting is welded at both ends in the field, so the low-carbon grade is preferred where post-weld annealing is not possible: it resists chromium carbide precipitation and intergranular attack in the heat-affected zone. WP304L has lower minimum strength (485 / 170 MPa against 515 / 205 MPa), so fittings are often dual certified to meet both grades.

Elbows, tees and reducers are formed hot or cold from seamless or welded pipe, solution annealed and pickled. Choose 304/304L fittings to match SS 304 / 304L pipe; move to SS 316 / 316L fittings where chlorides are present. Metals Fabrica supplies WP304, WP304L and dual-grade fittings and confirms the class and schedule against your line list.

  • Standards: ASTM A403 WP304 / WP304L; ASTM A182 F304 / F304L
  • Classes: WP-S, WP-W, WP-WX, WP-WU and CR (MSS SP-43)
  • Condition: solution annealed, pickled and passivated
  • Best for: welded systems in water, food, nitric acid and cryogenic service
TYPES & VARIANTS

Types of SS 304 / 304L Pipe Fittings

WP304L Long-Radius 90° and 45° Elbows

1.5D long-radius elbows to ASME B16.9 for most process lines; 1D short-radius elbows are used where space is tight and pressure drop is acceptable.

WP304 Equal and Reducing Tees

Seamless or welded tees with run and branch in the same or reduced size, used for headers and branch take-offs in 304 piping.

SS 304L Concentric and Eccentric Reducers

Reducers that step pipe size along a common centreline or with one flat side, often in schedule 10S for water and utility systems.

SS 304L Stub Ends and Caps

Short or long pattern stub ends for lap-joint flange connections, and butt-weld caps for closing line ends and future tie-in points.

Light-Wall MSS SP-43 Fittings in 304L

Schedule 5S and 10S fittings in class CR for low-pressure hygienic and water lines, where wall thickness must match thin-wall 304L pipe.

F304 / F304L Forged Fittings

Socket-weld and threaded elbows, tees, couplings and unions in Class 2000 to 9000 to ASME B16.11 for small-bore 304 lines.

SPECIFICATIONS

SS 304 / 304L Pipe Fittings Specifications

SpecificationDetails
Butt-weld standardASTM A403 / ASME SA403 WP304, WP304L (dual WP304/304L on request)
Forged standardASTM A182 / ASME SA182 F304, F304L
UNSS30400 (304), S30403 (304L)
Fitting classWP-S, WP-W, WP-WX, WP-WU; CR-S, CR-W
Dimension standardsASME B16.9, MSS SP-43; ASME B16.11, MSS SP-79, SP-83, SP-95, SP-97
Size range1/2" NB to 48" NB butt-weld; 1/8" to 4" forged
Wall thicknessSCH 5S to SCH XXS, to match the pipe; Class 2000, 3000, 6000, 9000 forged
Fitting typesElbows (45°, 90°, 180°, LR/SR), tees, crosses, reducers, caps, stub ends, couplings, unions, plugs, olets
Heat treatmentSolution annealed at 1040 °C (1900 °F) minimum and rapidly cooled; pickled and passivated
TestingPMI, dimensional and visual inspection, weld RT/UT per class, IGC test to ASTM A262 Practice E on request
DocumentationEN 10204 3.1 mill test certificate; EN 10204 3.2 on request

Confirm the fitting class, schedule and end preparation in your enquiry.

CHEMICAL COMPOSITION

SS 304 / 304L Pipe Fittings Chemical Composition

Weight %, maximum unless a range is shown, per ASTM A403 Table 1.
GradeUNSCMnSiPSCrNiN
WP304S304000.082.001.000.0450.03018.0 – 20.08.0 – 11.00.10
WP304LS304030.0302.001.000.0450.03018.0 – 20.08.0 – 12.00.10

Forged F304 / F304L to ASTM A182 have the same principal limits; check A182 for the forged grade.

MECHANICAL PROPERTIES

SS 304 / 304L Pipe Fittings Mechanical Properties

Minimum tensile requirements per ASTM A403 and ASTM A182, with typical physical properties.
GradeDensityMelting RangeTensile Strength, minYield Strength (0.2% Offset), minElongation, min
WP3048.00 g/cm³1400 – 1450 °C515 MPa (75 ksi)205 MPa (30 ksi)28% longitudinal
WP304L8.00 g/cm³1400 – 1450 °C485 MPa (70 ksi)170 MPa (25 ksi)28% longitudinal
F304 (A182)8.00 g/cm³1400 – 1450 °C515 MPa (75 ksi)205 MPa (30 ksi)30%; RA 50%
F304L (A182)8.00 g/cm³1400 – 1450 °C485 MPa (70 ksi)170 MPa (25 ksi)30%; RA 50%

Density and melting range are typical values, not specification requirements. A403 transverse elongation minimum is 20%.

EQUIVALENT GRADES

SS 304 / 304L Pipe Fittings Equivalent Grades

GradeUNSWerkstoff Nr.ENJISBSAFNORGOST
SS 304S304001.4301X5CrNi18-10SUS 304304S31Z7CN18-0908Х18Н10
SS 304LS304031.4306 / 1.4307X2CrNi19-11 / X2CrNi18-9SUS 304L304S11Z3CN18-1003Х18Н11

Equivalents are approximate material designations. For EN fittings the product standard is EN 10253-3 or EN 10253-4; order to the standard in your specification.

APPLICATIONS

SS 304 / 304L Pipe Fittings Applications

Dairy, Brewery and Beverage Lines

304L elbows, tees and reducers in product and CIP circuits, where welded joints must resist cleaning chemicals without carbide sensitisation.

Municipal and Industrial Water

Schedule 10S and 40S 304 fittings for potable, demineralised and low-chloride cooling water headers and pump connections, where they avoid rust staining and scale build-up.

Nitric Acid and Oxidising Chemicals

304L fittings perform well in nitric acid plants and oxidising media, provided intergranular corrosion testing confirms the annealed condition.

Cryogenic Gas Systems

Austenitic 304L keeps its toughness at very low temperatures, so its fittings are used on liquid nitrogen, oxygen and argon distribution lines.

HVAC and Building Services

Light-wall MSS SP-43 304 fittings for chilled-water, condensate and compressed-air systems where corrosion of carbon steel would shorten service life.

WHY METALS FABRICA

Why Choose Metals Fabrica for SS 304 / 304L Pipe Fittings?

  • 304 or 304L confirmed: we check whether your line class needs WP304, WP304L or dual-certified fittings before we quote.
  • Class and schedule matched: WP-S, WP-W, WP-WX or CR class and the wall thickness are reviewed against the pipe they will be welded to.
  • Complete 304 package: fittings quoted with SS 304 / 304L pipe and SS 304 / 304L flanges.
  • Certificates that match the marking: EN 10204 3.1 documents, with IGC tests or third-party inspection coordinated on request.
FAQ

SS 304 / 304L Pipe Fittings FAQs

WP304L limits carbon to 0.030% against 0.08% for WP304, which protects the weld zones from intergranular corrosion. WP304L has lower minimum strength, 485 MPa tensile and 170 MPa yield compared with 515 MPa and 205 MPa for WP304.

Yes. When the chemistry meets the WP304L limits and the tensile results meet WP304 minimums, the fitting can be marked and certified to both grades, so it can be installed wherever either is specified.

Only if your specification allows welded construction. WP304-S is seamless; WP304-W is welded with the fitting-maker’s welds radiographed. Many process specifications accept welded fittings above a certain size, so check the piping class.

A403 requires solution annealing after forming. Pickling removes the scale from annealing and welding, and passivation restores a clean chromium oxide surface; both are normally specified for 304 fittings in corrosive or hygienic service.

REQUEST A QUOTE

Request a Quote for SS 304 / 304L Pipe Fittings

List the grade (304, 304L or dual), fitting type, class, size, schedule, end preparation and quantity, and we will reply with price and availability.