ASTM A192 covers minimum-wall-thickness seamless carbon steel tubes for boilers and superheaters in high-pressure service. Its ASME counterpart, SA192, is used in boilers built to ASME Section I. The standard covers outside diameters from 1/2 in to 7 in (12.7–177.8 mm) and minimum walls from 0.085 in to 1.000 in (2.2–25.4 mm), and the general tube requirements come from ASTM A450/A450M.
A192 is a low-carbon, silicon-killed steel: carbon 0.06–0.18%, manganese 0.27–0.63% and silicon up to 0.25%. The low carbon gives the tube excellent ductility for expanding, bending and swaging, with a minimum tensile strength of 325 MPa (47 ksi) and a hardness limit of 77 HRB. Hot-finished tubes need no further heat treatment; cold-finished tubes are heat treated at 650 °C or higher after the final cold pass.
Because A192 tubes are ordered by minimum wall, the actual wall is always at or above the figure used in the pressure calculation. Where a higher-strength carbon steel tube is needed for the same duty, SA210 Grade A1 tube is the usual step up; for exchanger service without boiler pressure, compare ASTM A179 tube. Metals Fabrica checks A192 tube enquiries for OD, minimum wall, length and the flattening, flaring and hydrostatic tests your boiler code requires before quoting.
Tubes finished on the hot mill and used without further heat treatment, typically in larger outside diameters and heavier walls for headers and water walls.
Tubes cold drawn to closer diameter and wall tolerances and then heat treated at 650 °C or higher, suited to expanded joints in drums and headers.
A192 tubes are ordered on minimum wall, so the tolerance is entirely above the stated wall. Design engineers use the ordered figure directly in pressure calculations.
Tubes bent to boiler drawings or swaged at the ends for fitting into drums and headers, relying on the ductility of the low-carbon steel.
| Specification | Details |
|---|---|
| Standard | ASTM A192/A192M / ASME SA192 (UNS K01201) |
| General requirements | ASTM A450/A450M |
| Size range (standard scope) | 1/2" to 7" OD (12.7 – 177.8 mm) |
| Wall thickness | 0.085" to 1.000" (2.2 – 25.4 mm) minimum wall |
| Manufacturing type | Seamless, hot finished or cold drawn |
| Heat treatment | Hot-finished: none required; cold-finished: 650 °C (1200 °F) or higher after final cold pass |
| Ends | Plain end, bevelled end |
| Length | Fixed length, random length, cut length |
| Testing | Tension, flattening, flare and hardness tests; hydrostatic or non-destructive electric test on each tube |
| Documentation | EN 10204 3.1 mill test certificate; EN 10204 3.2 / third-party inspection coordinated when the order requires it |
Boiler tubes are ordered by outside diameter and minimum wall, not by nominal pipe size and schedule. State OD, minimum wall, length and quantity in your enquiry.
| Grade | UNS | C | Mn | P | S | Si |
|---|---|---|---|---|---|---|
| A192 | K01201 | 0.06 – 0.18 | 0.27 – 0.63 | 0.035 | 0.035 | 0.25 |
| Grade | Density | Tensile Strength, min | Yield Strength, min | Elongation in 50 mm, min | Hardness, max |
|---|---|---|---|---|---|
| A192 | 7.85 g/cm³ | 325 MPa (47 ksi) | 180 MPa (26 ksi) | 35% | 77 HRB (137 HBW) |
Density is a typical value, not an A192 requirement. Hardness may be tested by Brinell or Rockwell methods as permitted by A450/A450M.
| Grade | UNS | EN / DIN | JIS | BS | GB | IS |
|---|---|---|---|---|---|---|
| A192 | K01201 | P195GH (EN 10216-2) / St 35.8 (DIN 17175) | STB 340 (JIS G3461) | BS 3059-2 360 | 10 (GB 3087) | – |
Equivalents are approximate. Boiler regulations (for example ASME Section I or IBR in India) may only accept the named standard, so order to the standard in your specification.
Furnace water-wall and riser tubes in industrial and utility boilers, where A192's ductility allows bending to complex shapes and expanding into drums.
Smoke tubes and stay tubes in shell boilers and package units, where seamless low-carbon tube is easy to expand and seal-weld into tube plates.
Economiser coils and feedwater heater tubes that recover heat from flue gas or bled steam at moderate metal temperature and high water-side pressure.
Lower-temperature evaporator and economiser sections of HRSGs behind gas turbines, where carbon steel tube is adequate for the metal temperature.
Both are seamless carbon steel boiler tubes. SA210 A1 has higher carbon and a minimum tensile strength of 415 MPa against 325 MPa for A192, so it allows thinner walls; A192 is softer and easier to expand and bend.
A192 is for boilers and superheaters in high-pressure service, covers 1/2 in to 7 in OD and allows up to 0.25% silicon. A179 is a cold-drawn heat-exchanger and condenser tube up to 3 in OD with a lower hardness limit of 72 HRB.
The standard is written for minimum-wall tubes, so all wall tolerance is positive. This guarantees that the wall used in the boiler pressure calculation is never undercut.
ASTM A192 limits hardness to 77 HRB, or 137 HBW on the Brinell scale. The limit ensures the tubes can be expanded and flared without cracking.